Showing results: 46 - 60 of 77 items found.
-
AMPI-520 -
Amperis sl
The AMPI-520 digital meter is designed to measure impedance in short-circuit loops without tripping the differential protection, it also measures the protection tare, earth resistance, continuity and phase sequence check.
-
Bender Inc.
Various measuring and monitoring relays are available for the purpose of monitoring electrical quantities. In addition to overvoltage, undervoltage, frequency, unbalance, phase sequence, phase failure and loop monitoring, special solutions for specific applications are also possible: extended temperature ranges, sector-specific standards, compact design, country-specific profiles.
-
HIOKI E.E. Corp
Non- metalic voltage measurements Non- metalic measure voltage and detect phase sequence simultaneously 90 to 520 V AC 6 - 30 mm (0.24 - 1.18 in) core dia.
-
Extech 480403 -
Extech Instruments Corporation
The 480403 Phase Sequence and Motor Rotation Tester has a 40 to 600-Volt rated range for testing phase orientation of 3-phase power sources over a 2 to 400Hz frequency range. LEDs indicate phase orientation (clockwise or counter-clockwise) and whether each of the phases is live. In addition, it indicates rotation direction of the motor to ensure that it doesn't get damaged from incorrect wiring. Meter comes complete with cable and three large color coded alligator clips, pouch case, and 9V battery.
-
PC15250 -
Martindale Electric Co. Ltd
Quickly and simply prove continuity of all 3 lines. Identifies which are faulty and shows the sequence of phase rotation. Fast & effective method of identifying worn or unmarked cables, and ensuring 3-phase outlets and machinery are wired correctly.
-
Tenmars Electronics Co., Ltd.
*LCD display with maximum reading of 6000, plus decimal point.*Analog Bargraph.*AC voltage range: 0 to 600V.*DC voltage range: 0 to 600V.*Auto power off (15 minutes).*Frequency measurement.*AC and Frequency measurement with only one test lead.*Phase sequence test.*Phase conformity test.*Continuity test.*Double injection outer case.
-
Testboy GmbH
Using five glow lamps, the rotary field tester, Testboy TV 410N, indicates the presence of all three phases and, through their sequence, determines the correct order of the phases. The housing is made from impact-resistant, unbreakable ABS plastic, the fully insulated 4 mm sockets and the associated comprehensive and adaptable connection cable set provide safe testing and rapid determination of the phasing in a three-phase system.
-
STB Electrical Test Equipment, Inc
From the company who builds the popular analog ground fault detector comes the newest phase rotation indicator on the market. No other manufacturer offers a phase rotation indicator like STB's DX2 that will read up to 5kV! The phase rotation indicator is used to determine the phase sequence of three-phase voltages. This meter is most commonly used for phasing-in a power line which has supplied power to motors and plants. It is essential for testing departments of public utility systems for laboratory and field testing. The convenient and durable carrying case allows user to safely transport the unit to wherever the job takes them.
-
DARE Electronics
DARE has a complete line of AC or DC operated power monitors available in numerous package styles including 50 Hz, 60 Hz, and 400 Hz models. In addition, DARE has a series of external aircraft power monitors that continuously monitor the quality of electrical power in aircraft electrical systems, ground power equipment, auxiliary power units (APU?s), and other equipment for pre-determined over / under voltage conditions, over / under frequency conditions, loss of phase, improper phase sequence or phase rotation.
-
MI 3102 BT EurotestXE -
Metrel d.d.
MI 3102 BT EurotestXE is a multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. It supports AUTO SEQUENCE® testing of the TN, TT and IT earthing systems. ISFL measurements and the IMD tests can be performed. Besides, the MI 3102 BT EurotestXE enables on-line voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement and TRMS current measurement. EurotestXE is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
P-4 -
Sonel S.A.
Sonel P-4 is reliable, particularly durable and safe 2-pole testers, which enable testing voltage, circuit continuity and phase sequence. It has been designed for use in extreme conditions both in industry and commercial applications. Advanced technology, a high level of safety and user-friendliness are the key features of the P-line voltage testers.
-
CM3286 Series -
HIOKI E.E. Corp
Measure power ranging from 5 W at a low current of 60 mA to 360 kW. In addition to current, voltage, and power, measure simple integral power consumption and phase sequence. Discover manipulation of electric meters by comparing meter and integral power consumption measurements. Discover theft by measuring leakage current.
-
Mors Smitt Group
XM-series modular electronic monitoring relays *Voltage montoring models (1-phase or 3-phase) *3-phase network monitoring models (phase failure, sequence and asymmetry) *Current monitoring models (AC, DC) *Suited for 35mm rail (DIN) mountingFor general purpose, industrial applications, switching of AC or low DC voltages / resistive loads.
-
COMBI519 -
HT Italia Srl
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
COMBI521 -
HT Italia Srl
COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.